Dual-channel spectrum analyzer with balancing function

Dual-channel spectrum analyzer with balancing function
Product Detailed
Related Categories:Other Analysis Instruments
Dual-channel spectrum analyzer 1.Features High speed data collection 2.Suit for various industrial environments

RH822 Dual-channel spectrum analyzer

 

RH822 Dual-channel spectrum analyzer provides powerful dual-channel waveform and spectrum collection and analysis, offers many characteristics function, such as long time domain waveform, XPM, run up/down testing analysis and on site single/dual- plane dynamic balance measurement. It also has the advantages of small volume, light weight, good reliable and convenient to use, can meet the needs of precise inspection and fault diagnostic by professional analysts.     

 

Features

High speed data collection

High-performace processor ARM9 with 400MHz dominant frequency, Modular design, Optimized operation procedure, Greatly improved efficiency of data collection and analysis.

 

Suit for various industrial environments

Dustproof, waterproof, small volumn, light weight, convenient for long-distance carrying and bad industrial fields using.

 

Convenient to operate and use

Use embedded operation system Micrsoft Windows® CE, TFT true culor LCD, Humanization button setting, can be operated quickly.

 

Powerful Dual-channel analysis function

Besides scheduled data collection, RH822 provides powerful unscheduled data collection and analysis function, include:

  1).Time domain waveform, FFT analysis

2).Envelop Modulation, Cepstrum, Eigenvalue calculation

3).Long time domain waveform, Overall value trend

4).XPM, Axis trajectory

5).Run up/down testing analysis, Hammering impact response testing.

 

On site Single/ Dual-channel dynamic balance measurement

Users can have Single/ Dual dynamic on site balance measurement conveniently as prompted and repeatedly balancing operation according to different demands.

 

Main technical parameters

Items

Specification

Analog measurement

Channels

Channel 1:vibration(ICP accelerometer), AC/DC;

Channel 2:vibration(ICP accelerometer), AC/DC; Dual-channel synchronized measurement;

Rotating channel: external speed sensor

Transducer

Accelerometer, Velocity Pickups, Displacement Probes, photoelectricity speed sensor

Signal range

±40V

Signal type

Acceleration, Speed, Shifting, Voltage

Frequency Range

DC~40kHz, (AC/ICP input, Fmin=2Hz)

Lines

400,800,1600,3200,6400,12800

Time domain sampling

1024~32768

Window function type

Rectangle, Hanning, Hamming, Triangle, Blackman, Kaiser Window

Averaging type

Time damain, Spectrum

A/D conversion

16 bit

Analog Processing

Time domain waveform

Single/Dual channel waveform analysis, provide spectrum analysis, cepstrum analysis,enelope and Eigenvalue calculation according to the measuring time domain waveform data

Spectrum analysis

Single/ Dual channel spectrum analysis, provide fundamental and side frequency vernier

Long time domain waveform

Collection time can be typed in by users, the maximum length of data collection is depend on the balance storage apace.

Ovrall value trend

Minimum interval 0.1 second, maximum length 30000 points

XPM

Can display cross-power spectrum and phase difference spectrum simultaneously

Dynamic balance

Use influence coefficient to realize Single/ Dual on site dynamic balance

Hammering impact response testing

Measuring natural frequency

Run up/down testing analysis

Use equal time interval and equal rotating interval for measurement

Basic Index

Storage capacity

1GB

LCD

3.5’’ true color TFT LCD, 320x240 pixel,65536color, with backlight

Battery

Rechargeable Li-ion battery, working Time (Continuous) >8 Hours; charging time: 4 Hours

Temperature Range

(-10~+50)°C, storage temperature range: (-20~+60)°C

Buttons

22 buttons (with numeric type in), with backlight

Communication

USB

Dimensions

190mm x 110mm x 38mm (without cover)

Protection grade

IP65, dustproof, waterproof

Weight

715g

Dual-channel spectrum analyzer with balancing function



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.